324 research outputs found

    Association between cognitive performance and cortical glucose metabolism in patients with mild Alzheimer's disease

    Get PDF
    Background: Neuronal and synaptic function in Alzheimer's disease (AD) is measured in vivo by glucose metabolism using positron emission tomography (PET). Objective: We hypothesized that neuronal activation as measured by PET is a more sensitive index of neuronal dysfunction than activity during rest. We investigated if the correlations between dementia severity as measured with the Mini Mental State Examination (MMSE) and glucose metabolism are an artifact of brain atrophy. Method: Glucose metabolism was measured using {[}F-18]fluorodeoxyglucose PET during rest and activation due to audiovisual stimulation in 13 mild to moderate AD patients (MMSE score >= 17). PET data were corrected for brain atrophy. Results: In the rest condition, glucose metabolism was correlated with the MMSE score primarily within the posterior cingulate and parietal lobes. For the activation condition, additional correlations were within the primary and association audiovisual areas. Most local maxima remained significant after correcting for brain atrophy. Conclusion: PET activity measured during audiovisual stimulation was more sensitive to functional alterations in glucose metabolism in AD patients compared to the resting PET. The association between glucose metabolism and MMSE score was not dependent on brain atrophy. Copyright (C) 2005 S. Karger AG, Basel

    Medial prefrontal cortex serotonin 1A and 2A receptor binding interacts to predict threat-related amygdala reactivity

    Get PDF
    Background\ud The amygdala and medial prefrontal cortex (mPFC) comprise a key corticolimbic circuit that helps shape individual differences in sensitivity to threat and the related risk for psychopathology. Although serotonin (5-HT) is known to be a key modulator of this circuit, the specific receptors mediating this modulation are unclear. The colocalization of 5-HT1A and 5-HT2A receptors on mPFC glutamatergic neurons suggests that their functional interactions may mediate 5-HT effects on this circuit through top-down regulation of amygdala reactivity. Using a multimodal neuroimaging strategy in 39 healthy volunteers, we determined whether threat-related amygdala reactivity, assessed with blood oxygen level-dependent functional magnetic resonance imaging, was significantly predicted by the interaction between mPFC 5-HT1A and 5-HT2A receptor levels, assessed by positron emission tomography.\ud \ud Results\ud 5-HT1A binding in the mPFC significantly moderated an inverse correlation between mPFC 5-HT2A binding and threat-related amygdala reactivity. Specifically, mPFC 5-HT2A binding was significantly inversely correlated with amygdala reactivity only when mPFC 5-HT1A binding was relatively low.\ud \ud Conclusions\ud Our findings provide evidence that 5-HT1A and 5-HT2A receptors interact to shape serotonergic modulation of a functional circuit between the amygdala and mPFC. The effect of the interaction between mPFC 5-HT1A and 5-HT2A binding and amygdala reactivity is consistent with the colocalization of these receptors on glutamatergic neurons in the mPFC

    The effects of weather and climate change on dengue

    Get PDF
    There is much uncertainty about the future impact of climate change on vector-borne diseases. Such uncertainty reflects the difficulties in modelling the complex interactions between disease, climatic and socioeconomic determinants. We used a comprehensive panel dataset from Mexico covering 23 years of province-specific dengue reports across nine climatic regions to estimate the impact of weather on dengue, accounting for the effects of non-climatic factors

    The potential impact of the next influenza pandemic on a national primary care medical workforce

    Get PDF
    BACKGROUND: Another influenza pandemic is all but inevitable. We estimated its potential impact on the primary care medical workforce in New Zealand, so that planning could mitigate the disruption from the pandemic and similar challenges. METHODS: The model in the "FluAid" software (Centers for Disease Control and Prevention, CDC, Atlanta) was applied to the New Zealand primary care medical workforce (i.e., general practitioners). RESULTS: At its peak (week 4) the pandemic would lead to 1.2% to 2.7% loss of medical work time, using conservative baseline assumptions. Most workdays (88%) would be lost due to illness, followed by hospitalisation (8%), and then premature death (4%). Inputs for a "more severe" scenario included greater health effects and time spent caring for sick relatives. For this scenario, 9% of medical workdays would be lost in the peak week, and 3% over a more compressed six-week period of the first pandemic wave. As with the base case, most (64%) of lost workdays would be due to illness, followed by caring for others (31%), hospitalisation (4%), and then premature death (1%). CONCLUSION: Preparedness planning for future influenza pandemics must consider the impact on this medical workforce and incorporate strategies to minimise this impact, including infection control measures, well-designed protocols, and improved health sector surge capacity

    Test-retest variability of high resolution positron emission tomography (PET) imaging of cortical serotonin (5HT2A) receptors in older, healthy adults

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Position emission tomography (PET) imaging using [<sup>18</sup>F]-setoperone to quantify cortical 5-HT<sub>2A </sub>receptors has the potential to inform pharmacological treatments for geriatric depression and dementia. Prior reports indicate a significant normal aging effect on serotonin 5HT<sub>2A </sub>receptor (5HT<sub>2A</sub>R) binding potential. The purpose of this study was to assess the test-retest variability of [<sup>18</sup>F]-setoperone PET with a high resolution scanner (HRRT) for measuring 5HT<sub>2A</sub>R availability in subjects greater than 60 years old. Methods: Six healthy subjects (age range = 65–78 years) completed two [<sup>18</sup>F]-setoperone PET scans on two separate occasions 5–16 weeks apart.</p> <p>Results</p> <p>The average difference in the binding potential (BP<sub>ND</sub>) as measured on the two occasions in the frontal and temporal cortical regions ranged between 2 and 12%, with the lowest intraclass correlation coefficient in anterior cingulate regions.</p> <p>Conclusion</p> <p>We conclude that the test-retest variability of [<sup>18</sup>F]-setoperone PET in elderly subjects is comparable to that of [<sup>18</sup>F]-setoperone and other 5HT<sub>2A</sub>R radiotracers in younger subject samples.</p

    Impact of combined 18F-FDG PET/CT in head and neck tumours

    Get PDF
    To compare the interobserver agreement and degree of confidence in anatomical localisation of lesions using 2-[fluorine-18]fluoro-2-deoxy-D-glucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) and 18F-FDG PET alone in patients with head and neck tumours. A prospective study of 24 patients (16 male, eight female, median age 59 years) with head and neck tumours was undertaken. 18F-FDG PET/CT was performed for staging purposes. 2D images were acquired over the head and neck area using a GE Discovery LS™ PET/CT scanner. 18F-FDG PET images were interpreted by three independent observers. The observers were asked to localise abnormal 18F-FDG activity to an anatomical territory and score the degree of confidence in localisation on a scale from 1 to 3 (1=exact region unknown; 2=probable; 3=definite). For all 18F-FDG-avid lesions, standardised uptake values (SUVs) were also calculated. After 3 weeks, the same exercise was carried out using 18F-FDG PET/CT images, where CT and fused volume data were made available to observers. The degree of interobserver agreement was measured in both instances. A total of six primary lesions with abnormal 18F-FDG uptake (SUV range 7.2–22) were identified on 18F-FDG PET alone and on 18F-FDG PET/CT. In all, 15 nonprimary tumour sites were identified with 18F-FDG PET only (SUV range 4.5–11.7), while 17 were identified on 18F-FDG PET/CT. Using 18F-FDG PET only, correct localisation was documented in three of six primary lesions, while 18F-FDG PET/CT correctly identified all primary sites. In nonprimary tumour sites, 18F-FDG PET/CT improved the degree of confidence in anatomical localisation by 51%. Interobserver agreement in assigning primary and nonprimary lesions to anatomical territories was moderate using 18F-FDG PET alone (kappa coefficients of 0.45 and 0.54, respectively), but almost perfect with 18F-FDG PET/CT (kappa coefficients of 0.90 and 0.93, respectively). We conclude that 18F-FDG PET/CT significantly increases interobserver agreement and confidence in disease localisation of 18F-FDG-avid lesions in patients with head and neck cancers

    Initial clinical experience with frameless optically guided stereotactic radiosurgery/radiotherapy in pediatric patients

    Get PDF
    The objective of this study is to report our initial experience treating pediatric patients with central nervous system tumors using a frameless, optically guided linear accelerator. Pediatric patients were selected for treatment after evaluation by a multidisciplinary neuro-oncology team including neurosurgery, neurology, pathology, oncology, and radiation oncology. Prior to treatment, all patients underwent treatment planning using magnetic resonance imaging (MRI) and treatment simulation on a standard computed tomography scanner (CT). For CT simulation, patients were fitted with a customized plastic face mask with a bite block attached to an optical array with four reflective markers. After ensuring adequate reproducibility, these markers were tracked during treatment by an infra-red camera. All treatments were delivered on a Varian Trilogy linear accelerator. The follow-up period ranges from 1–18 months, with a median follow-up of 6 months. Nine patients, ages ranging from 12 to 19 years old (median age 15 years old), with a variety of tumors have been treated. Patients were treated for juvenile pilocytic astrocytoma (JPA; n = 2), pontine low-grade astrocytoma (n = 1), pituitary adenoma (n = 3), metastatic medulloblastoma (n = 1), acoustic neuroma (n = 1), and pineocytoma (n = 1). We followed patients for a median of 12 months (range 3–18 months) with no in-field failures and were able to obtain encouraging toxicity profiles. Frameless stereotactic optically guided radiosurgery and radiotherapy provides a feasible and accurate tool to treat a number of benign and malignant tumors in children with minimal treatment-related morbidity

    Partial volume correction strategies for quantitative FDG PET in oncology

    Get PDF
    Purpose: Quantitative accuracy of positron emission tomography (PET) is affected by partial volume effects resulting in increased underestimation of the standardized uptake value (SUV) with decreasing tumour volume. The purpose of the present study was to assess accuracy and precision of different partial volume correction (PVC) methods. Methods: Three methods for PVC were evaluated: (1) inclusion of the point spread function (PSF) within the reconstruction, (2) iterative deconvolution of PET images and (3) calculation of spill-in and spill-out factors based on tumour masks. Simulations were based on a mathematical phantom with tumours of different sizes and shapes. Phantom experiments were performed in 2-D mode using the National Electrical Manufacturers Association (NEMA) NU2 image quality phantom containing six differently sized spheres. Clinical studies (2-D mode) included a test-retest study consisting of 10 patients with stage IIIB and IV non-small cell lung cancer and a response monitoring study consisting of 15 female breast cancer patients. In all studies tumour or sphere volumes of interest (VOI) were generated using VOI based on adaptive relative thresholds. Results: Simulations and experiments provided similar results. All methods were able to accurately recover true SUV within 10% for spheres equal to and larger than 1 ml. Reconstruction-based recovery, however, provided up to twofold better precision than image-based methods. Cl
    corecore